- Generators/motors, Transformers, Transmission lines
- Three-phase short circuit, Fault currents using Zbus
- The selection of circuit breakers
- Sequence components and networks
- Single-line-to ground, Line-to-line, and Double-line-to ground faults, and Open conductor
- Practical examples
- Fuses, and Fuse coordination and selection
- Practical examples on fuses selection and coordination
- Transformer fusing
- Automatic circuit reclosers
- Reclosers ratings and control
- Examples on reclosers coordination
- Relays: Electromechanical, Solid state, and Microprocessor-based relays
- OC relays and exercises
- Factors affecting transformer protection
- Magnetizing inrush current
- Magnetizing inrush current harmonics
- Sympathetic inrush current
- Protection against incipient faults
- Differential protection of ? / transformers
- Differential protection of multi-winding transformers
- Gas detection
- Sudden pressure
- Transformer overcurrent protection
- Principles of differential protection
- Generators internal faults
- System disturbances and operational hazards
- Typical protection of direct connected generators
- Connection of generator protection
- Turn to turn fault protection
- Practical examples
- Back up protection
- Ground fault protection
- Rotor protection
- Loss of citation protection
- Potential motor hazards
- Motor characteristics involved in protection
- Induction motor equivalent circuit
- General motor protection
- Phase-fault protection
- Differential protection
- Ground-fault protection
- Thermal and locked-rotor protection
- Locked-rotor protection for large motors (21)
- System unbalance and motors
- Unbalance and phase rotation protection
- Undervoltage protection
- Bus transfer and reclosing
- Repetitive starts and jogging protection
- Multifunction microprocessor motor protection units
- Synchronous motor protection
- Summary: typical protection for motors
- Practical considerations of motor protection
- Coordination of protective devices
- Radial line protection strategy
- Clearing temporary faults
- Clearing permanent faults
- Recloser-fuse coordination
- OC relays coordination
- Phase and ground relays
- Procedure for instantaneous relay setting
- Over current protection
- OC protection of radial lines, loop with one source, and of multiple loop systems
- How V/I=Z makes a distance relay
- Distance relay characteristics
- Protection zones of distance relays
- Practical examples and exercises
- Principles and applications
- Pilot protection systems
- General concepts of pilot communication
- Unit protection pilot schemes
- Single phase comparison blocking
- Dual phase comparison unblocking
- Bus faults
- Bus protection requirement
- Bus differential protection for different bus arrangements
- Steady state stability
- Transient stability
- Equal area criterion
- Relay operation and transient stability condition
- Impedance measured by relays during power swing
- Out of step detection by distance relays
- Synchrophasors based out of step relays