- Electrocution at Low vs Medium Voltage
- Arc Flash
- Qualified Person
- Approach Boundaries
- Utility and Industrial One lines
- Reliability Requirements
- Overhead and Underground Systems
- Regulated Systems
- Copper vs Aluminum Design
- Voltage Ratings
- Insulation Ratings
- 100%, 133%, 173% Insulation Levels
- Shielding Requirements
- Electric Fields
- Terminating MV
- Conductors
- Orientation of Overhead Lines
- Core and Coil Design
- Aluminum and Copper Windings
- Tank Constructio
- Loss Evaluation
- Efficiency
- Regulation
- Spot Network Design
- Network Protectors
- Network Protector
- Relay Operation
- Directional Protection Requirements
- Corona
- Surface Tracking
- Voltage Stress
- Sensing Partial
- Discharge
- Component Failure
- Resistance Grounding
- Solid Grounding
- Ungrounded Delta
- Charging Current
- Effect of Ground Faults on Delta Voltage
- Lightning and Switching Surges
- Classes of Surge Arresters
- MCOV Ratings – (Maximum Continuous Operating Voltage)
- TOV – (Maximum Temporary Over Voltage Capability)
- Protective Characteristics
- Surge Arrester Selection
- Energy Capability
- Effect of Grounding on Arrestor Selection
- Insulation Coordination
- Ratings
- Selection Process
- Accuracy
- Saturation
- Excitation
- Curves
- Burden Calculation
- Momentary Ratings
- Vacuum, Air, Oil, SF6 Designs,
- Symmetrical Interrupting Rating
- K-Rated Voltage Factor, Close and Latch Capability
- Application on Feeder Circuits
- Recloser Setting
- Continuous Current and Interrupting Ratings
- Medium Voltage Switches
- Load Rating
- Close and Latch
- Rating
- Short Time Rating
- Expulsion vs Current Limiting
- Fuse Characteristics
- E and R Rated Fuses
- Fuse Cutouts
- Medium Voltage Protection
- Relays
- Circuit Breakers
- R and E Rated Fuses
- Short Circuit vs Overcurrent Protection
- Protection with Fuses – 300%
- Overcurrent Protection with Relays – 600%
- Short Circuit Damage Characteristics
- Relay “Reach” for End of Line Faults
- Requirements
- Decrement Curves
- Thermal Damage Curves
- Reactive
- Capability Curves
- Differential Protection
- Protection Requirements
- Motor Management Relays
- Circuit
- Breaker Protection
- Relaying
- Class R Rated Fuses
- ANSI C57 Thru Fault Curves
- Impact of Transformer Winding
- Configuration
- Overview of Differential Protection
- Inrush and Harmonic Restraint